意昂体育4|意昂4官方网站

      CN/EN

      产品与市场

      S2126

      特点

      ● 优异的耐漏电起痕性,CTI≥600V
      优秀的机械加工性能
      电性能与FR-4.0相当

      应用领域

      电源基板、电子游戏机、冰箱、洗衣机、空调等
      • 产品性能
      • 产品证书
      • 资料下载
      Items Method Condition Unit Typical Value
      Tg IPC-TM-650 2.4.25 DSC 130
      CTE (Z-axis) IPC-TM-650 2.4.24 Before Tg ppm/℃ 60
      After Tg ppm/℃ 340
      50-260℃ % 5.2
      Thermal Stress IPC-TM-650 2.4.13.1 288℃, solder dip -- 30S No delamination
      Volume Resistivity IPC-TM-650 2.5.17.1 After moisture resistance MΩ.cm 5.5 x 108
      E-24/125 MΩ.cm 5.3 x 106
      Surface Resistivity IPC-TM-650 2.5.17.1 After moisture resistance 6.7 x 107
      E-24/125 2.5 x 106
      Arc Resistance IPC-TM-650 2.5.1 D-48/50+D-4/23 s 140
      Dielectric Breakdown IPC-TM-650 2.5.6 D-48/50+D-4/23 kV 45+kV NB
      Dissipation Constant (Dk) IPC-TM-650 2.5.5.9 1MHz -- 4.6
      IEC 61189-2-721 10GHz --
      Dissipation Factor (Df) IPC-TM-650 2.5.5.9 1MHz -- 0.016
      IEC 61189-2-721 10GHz --
      Peel Strength (1oz HTE copper foil) IPC-TM-650 2.4.8 A N/mm
      After thermal Stress 288℃,10s N/mm 1.9
      125℃ N/mm 1.7
      Flexural Strength LW IPC-TM-650 2.4.4 A MPa 410
      CW IPC-TM-650 2.4.4 A MPa 340
      Water Absorption IPC-TM-650 2.6.2.1 E-1/105+D-24/23 % 0.07
      CTI IEC60112 A Rating PLC 0
      Flammability UL94 C-48/23/50 Rating V-0
      E-24/125 Rating V-0

      Remarks:

      1. Specification sheet: IPC-4101/12 , is for your reference only.

      2. All the typical value is based on the 1.6mm specimen.

      3. All the typical values listed above are for your reference only and not intended for specification. Please contact Shengyi Technology Co., Ltd. for detailed information. All rights from this data sheet are reserved by Shengyi Technology Co., Ltd.

      Explanation:C=Humidity conditioning, D=Immersion conditioning in distilled water,E=Temperature conditioning

      The first digit following the letter indicates the duration of preconditioning in hours, the second digit the preconditioning temperature in and the third digit the relative humidity.